Fanuc 30I Parameter Manual Pdf4/21/2021
PORT NUMBER Set this item to 0 when it is used as the (UDP) FOCAS2Ethernet function.Chapter 8, EMBEDDED ETHERNET FUNCTION, consists of the following sections: 8.1 EMBEDDED ETHERNET PORT AND PCMCIA ETHERNET CARD.602 8.2 SETTING UP THE EMBEDDED ETHERNET FUNCTION.605 8.3 SWITCHING BETWEEN THE EMBEDDED ETHERNET DEVICES.EMBEDDED ETHERNET OPERATIONS.646 8.5 RESTART OF THE EMBEDDED ETHERNET.651 8.6 MAINTENANCE SCREEN FOR EMBEDDED ETHERNET FUNCTION.652 8.7 LOG SCREEN OF THE EMBEDDED ETHERNET FUNCTION.657 - 601 - 8.EMBEDDED ETHERNET FUNCTION B-63945EN038.1 EMBEDDED ETHERNET PORT AND PCMCIA ETHERNET CARD The embedded Ethernet function can be used by selecting one of two types of devices: the embedded Ethernet port and PCMCIA Ethernet card.A selection can also be made to stop the embedded Ethernet function.
The PCMCIA Ethernet card is to be inserted into the memory card slot for temporary communication. CAUTION 1 When using the embedded Ethernet function for the first time, set an IP address and other items carefully as instructed by the network administrator, then perform a sufficient communication test. Note that an incorrect IP address or other setting may cause a communication failure on the entire network. A unit such as a PC situated in the same network can increase the communication processing load on the CNC even if the unit is not communicating with the CNC. Use a router or the like to separate the network including the CNC from the other networks. NOTE 1 The embedded Ethernet port of FANUC Series 32i-A is available as an option. Use the PCMCIA Ethernet card designated by FANUC. The PCMCIA Ethernet card is used for FANUC LADDER-III or SERVO GUIDE. Use the PCMCIA Ethernet card just for temporary communication as described above. Avoid using the card for continuous communication. The PCMCIA Ethernet card is inserted into a memory card slot, with a part of the card left uninserted. When using the PCMCIA Ethernet card, take great care not to damage the card by hitting the protruding part of the card. When the card becomes unnecessary, remove the card immediately, in order to prevent any damage to the card. B-63945EN03 8.EMBEDDED ETHERNET FUNCTIONRelated NC parameters 14880 7 6 5 4 3 2 1 0 ETH Input type Setting input Data type Bit 0 ETH The embedded Ethernet function (embedded Ethernet port or PCMCIA Ethernet card) is: 0: Used. Fanuc 30I Parameter Series 656F AndNot used. NOTE This parameter is valid with series 656F and edition 06 or later. Selection of embedded Ethernet with the 300is, 310is, and 320is of stand-alone type Input type Parameter input Data type Word Valid data range 0 to 3 Set embedded Ethernet usable with the 300is, 310is, and 320is of stand-alone type. For the embedded Ethernet port, the connector (CD38A) for Ethernet on the control unit is used. For the PCMCIA Ethernet card, the card slot on the side of the display unit is used. For the PCMCIA Ethernet card, the card slot (CNM1B) on the control unit is used. For the embedded Ethernet port, the connector (CD38S) for Ethernet on the rear of the display unit is used. No.14896 embedded Ethernet port PCMCIA Ethernet card Port in the CNC Memory card slot on a side of the display unit 0 Port in the CNC 1 Memory card slot in the CNC 2 Port in the rear of the display unit Memory card slot on a side of the display unit 3 Port in the rear of the display unit Memory card slot in the CNC NOTE This parameter is valid with the FS300is310is320is-A of stand-alone type, and series 656F and edition 08 or later. EMBEDDED ETHERNET FUNCTION B-63945EN03Notes on using Ethernet with Windows CE of FS300is310is320is-A With the FS300is310is320is-A, the Ethernet interface on Windows CE may be used by both of the embedded Ethernet function of the CNC and application software on Windows CE. NOTE 1 When the FS300is310is320is-A of LCD-mounted type is used and the PCMCIA Ethernet card is selected for the embedded Ethernet function, application software on Windows CE cannot use the embedded Ethernet port. Setting of the FOCAS2Ethernet Function This subsection describes the settings required to operate the FOCAS2Ethernet function.Notes on using the FOCAS2Ethernet function for the first time NOTE 1 When running users original application software created by using the FOCAS2Ethernet function, use the embedded Ethernet port. The FOCAS2Ethernet function allows up to five FOCAS2Ethernet clients to be connected to one CNC. Concurrent access by multiple applications or personal computers may overload the CNC, reducing the communication speed. EMBEDDED ETHERNET FUNCTION B-63945EN038.2.1.1 Operation on the FOCAS2Ethernet setting screen On the Ethernet parameter setting screen, set the parameters for operating the FOCAS2Ethernet function.Procedure 1 Press the function key. Soft keys EMBED PORT and PCMCIA LAN appear. When there is no soft keys, press the continue key.) 3 To display the Ethernet Setting screen for the embedded Ethernet port or the PCMCIA Ethernet card, press soft key EMBED PORT or PCMCIA LAN, respectively. Press soft keys COMMON and FOCAS2 and then enter parameters for the items that appear. NOTE 1 The parameters for the embedded Ethernet port and the parameters for the PCMCIA Ethernet card are independent of each other. ![]() B-63945EN03 8.EMBEDDED ETHERNET FUNCTIONCOMMON screen (BASIC) Press soft key COMMON. COMMON screen (BASIC)Settings items Item DescriptionDisplay items IP ADDRESS Specify the IP address of the embedded Ethernet. SUBNET MASK (Example of specification format: 192.168.0.100) Specify a mask address for the IP addresses of the ROUTER IP network. ADDRESS (Example of specification format: 255.255.255.0) Specify the IP address of the router. Specify this item when the network contains a router. Example of specification format: 192.168.0.253) Item Description MAC ADDRESS Embedded Ethernet MAC address AVAILABLE Enabled device of the embedded Ethernet. DEVICE Either the embedded Ethernet port or the PCMCIA Ethernet card is displayed. EMBEDDED ETHERNET FUNCTION B-63945EN03FOCAS2 screen Press soft key FOCAS2. FOCAS2 screenSetting items Item Description PORT NUMBER Specify a port number to be used with the (TCP) FOCAS2Ethernet function.
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |